SH115B insulating oil dielectric loss and resistivity tester is a high-precision instrument with integrated structure for measuring dielectric loss angle and volume resistivity of insulating oil and other liquid insulating media. The main components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC test power supply, standard capacitor, megger, DC high voltage source are integrated inside. The heating part adopts the currently advanced high-frequency induction heating method, which has the advantages of non-contact between the oil cup and the heating body, uniform heating, fast speed and convenient control. AC test power supply adopts AC-DC-AC conversion mode to effectively avoid the impact of mains voltage and frequency fluctuation on the accuracy of dielectric loss test. Even if the generator generates electricity, the instrument can operate correctly. The internal standard capacitor is SF6 gas-filled three-pole capacitor. The dielectric loss and capacitance of the capacitor are not affected by ambient temperature, humidity, etc., to ensure that the accuracy of the instrument is consistent after a long time of use, and the measurement of resistivity complies with GB/T5654.
The internal part of the instrument adopts full digital technology, all intelligent automatic measurement, multiple mode measurement, and is equipped with a large screen (320 × 240) Touch display, full Chinese menu, Chinese prompt for each step, test results can be printed out, and operators can use it skillfully without professional training.
Transformer Insulating Oil Tester Electrical Resistivity Meter Insulation Oil Tester Transformer Oil Dielectric Loss Test Equipment
Insulating Oil Measuring Instruments Dielectric Loss Angle and Resistivity Tester
Oil Dielectric Loss Tester Oil Resistivity And Dielectric Loss Tester
Insulating Oil Dielectric Loss And Resistivity Tester SH115B(Automatic-cleaning)
Technical parameters
1 |
Conditions of use |
-15℃∽40℃ RH<80% |
|
2 |
Electrical source |
AC 220V±10% Unrestricted frequency |
|
3 |
AC high voltage output |
400V∽2200V ±2% every100V 50VA |
|
4 |
DC high voltage output |
200V∽600V ±2% |
|
5 |
Temperature controlled induction furnace |
The most powerful500W |
|
6 |
Temperature control range |
<100℃ |
|
7 |
Temperature control error |
±0.5℃ |
|
8 |
Resolution of temperature measurement |
0.1℃ |
|
9 |
Temperature control of time |
At room temperature to90℃ Less than20min |
|
10 |
Measuring range |
tgδ C x R |
Unlimited 15PF-300PF 10M-10T |
11 |
resolution |
△ tgδ: △ Cx : △ Rx : |
0.001% 0.01pF 0.01 |
12 |
Fine degree |
△ tgδ: △ Cx : △ Rx : |
±(reading*0.5%+0.040%) ±(reading*0.5%+0.5PF) ±reading * 10% |
13 |
Relative dielectric constant |
εr |
According to the Cx Automatic calculation with the same precision Cx |
14 |
Volume resistivity |
ρ |
According to the Rx Automatic calculation with the same precision Rx |
15 |
Overall dimensions |
450(L)×310(W)×360(H) |
|
16 |
Heavy volume |
20Kg |
Company Introduction
Shandong Shengtai Instruments Co., Ltd. is specialized in the research and production of experimental testing instruments and industrial testing instruments. It is a professional instrument company integrating instrument research and development, manufacturing, sales and service. Its products are widely used in food, flour, grain and oil, Feed, electricity, petrochemical, industrial oil, aerospace, coal quality and other industries.
For more than 10 years, Shengtai has always been adhering to the "first-class service, customer first" as the purpose, "reasonable price, honesty and trustworthiness" as the business policy. Adhere to technical innovation, with rich knowledge of the technical team and experienced, thoughtful after-sales service team.
Shengtai instrument as one of the most large-scale and competitive enterprises in the industry, with the strength of technology research and development, professional technical knowledge and innovative design concept, in the model improvement, Significant technical breakthrough has been achieved in the development of function expansion and intelligent control system.
OUR service
After-sales service commitment, our company to sell the product after-sales service commitment: warranty period of one year, long-term technical support outside the warranty period. During the warranty period, the seller shall bear the cost of the replacement of the equipment, the freight and maintenance of the instrument; outside the warranty period, the seller shall waive the maintenance fee and charge only the cost of the basic materials and freight charges when the instrument is malfunctioning and the seller shall not charge the maintenance fee during the warranty period.
Packing list of insulating oil dielectric loss resistivity meter
S/N |
Name |
Quantity |
Unit |
Remarks |
1 |
Instrument host |
1 |
set |
|
2 |
Oil cup
|
1 |
piece |
|
3 |
Test temperature sensing wire |
1 |
piece |
|
4 |
Data acquisition line |
1 |
piece |
|
5 |
Inspect 2KV high-voltage test line |
1 |
piece |
|
6 |
Send to test line |
1 |
piece |
Black/long/clip at one end/connector at one end |
7 |
Measuring cup |
1 |
piece |
50ml |
8 |
power cord |
1 |
piece |
|
9 |
instructions |
1 |
copy |
|
10 |
Packing list |
1 |
copy |
|
11 |
Certificate warranty card |
1 |
copy |
|